ASTM-B788 › Standard Practice for Installing Factory-Made Corrugated Aluminum Culverts and Storm Sewer Pipe
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This practice describes procedures, soils, and soil placement for the proper installation of corrugated aluminum culverts and storm sewers in either trench or projection installations. A typical trench installation is shown in Fig. 1, and a typical embankment (projection) installation is shown in Fig. 2. The pipes described in this practice are manufactured in a factory and furnished to the job in lengths ordinarily from 10 to 30 ft [3 to 9 m], with 20 ft [6m] being common, for field joining.
1.2 This practice is applicable to either inch-pound units as B788 or to SI units as B788M. Inch-pound units are not necessary equivalent to SI units. SI units are shown in the text in brackets, and they are the applicable values for metric installation.
1.3
Keywords
aluminum pipe; corrugated aluminum pipe; culvert; installation-underground; sewers; ICS Number Code 91.140.80 (Drainage systems)
To find similar documents by ASTM Volume:
02.02 (Aluminum and Magnesium Alloys)
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-B0788_B0788M-09R20
Revision Level
2009 R20 EDITION
Status
Current
Modification Type
Revision
Publication Date
Sept. 30, 2020
Document Type
Practice
Page Count
5 pages
Committee Number
B07.08