ISO-81060-2 › Non-invasive sphygmomanometers - Part 2: Clinical investigation of intermittent automated measurement type
The following bibliographic material is provided to assist you with your purchasing decision:
Included in this current edition are the following subparts:
FOR 3RD EDITION AMENDMENT 1 SEE - Jan. 1, 2020
FOR 3RD EDITION AMENDMENT 2 SEE - March 1, 2024
This document specifies the requirements and methods for the clinical investigation of me equipment used for the intermittent non-invasive automated estimation of the arterial blood pressure by utilizing a cuff.
This document is applicable to all sphygmomanometers that sense or display pulsations, flow or sounds for the estimation, display or recording of blood pressure. These sphygmomanometers need not have automatic cuff inflation.
This document covers sphygmomanometers intended for use in all patient populations (e.g. all age and weight ranges), and all conditions of use (e.g. ambulatory blood pressure monitoring, stress testing blood pressure monitoring and blood pressure monitors for the home healthcare environment for self-measurement as well as use in a professional healthcare facility).
EXAMPLE Automated sphygmomanometer as given in IEC 80601-2-30 undergoing clinical investigation according to this document.
This document specifies additional disclosure requirements for the accompanying documents of sphygmomanometers that have passed a clinical investigation according to this document.
This document is not applicable to clinical investigations of non-automated sphygmomanometers as given in ISO 81060-1 or invasive blood pressure monitoring equipment as given in IEC 60601-2-34.
To find similar documents by classification:
11.040.10 (Anaesthetic, respiratory and reanimation equipment Including medical gas installations)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
UL-2900-2-1Software Cybersecurity for Network-Connectable Products, Part 2-1: Particular Requirements for Network Connectable Components of Healthcare and Wellness Systems
ANSI/AAMI-ES60601-1
Medical electrical equipment, Part 1: General requirements for basic safety and essential performance (IEC 60601-1:2005, MOD)
ANSI/AAMI/ISO-8638
Cardiovascular implants and extracorporeal systems - Extracorporeal blood circuit for hemodialyzers, hemodiafilters and hemofilter
Document Number
ISO 81060-2:2018
Revision Level
3RD EDITION
Status
Current
Publication Date
Nov. 1, 2018
Committee Number
ISO/TC 121/SC 3